Cerberus Addressable Fire Panel Manual Fc924

Posted on  by  admin
Cerberus Addressable Fire Panel Manual Fc924 Average ratng: 3,8/5 1168 votes
Cerberus Addressable Fire Panel Manual Fc924

C o a s t G u a r d A p p r o v a l N u m b e r: 1 6 1.0 0 2 /6 0 /0 E x p ir e s: 1 9 F e b r u a r y 2 0 2 1 FI R E PR O TEC TI VE SYSTEM SI EM EN S I N D U STR Y, I N C. 8 F ERNW OO D DRI VE FL O R H AM PAR K N J 07932 D esi go Fi r e S af et y an d C er be r us P R O C o n si st i n g o f co n t rol p a n e l s, i n i t i a t i n g d e vi ce s, n o t i f i ca t i o n d e vi ce s, a n d a cce sso ri e s i d en t i f i ed i n A p p r o ve d C om p o n en t Li st w h i ch i s i d e n t i f i ed b e l o w. I D EN TI FYI N G D ATA: S i em en s m an ua l: FC 2 02 5/ FC 2 05 0/ FC 9 22 / FC 92 4 Fi r e A l ar m C on t r ol Pa ne l M ai ne A p pl i cat i on, D oc um ent A6V1 0519176 enUSa. A pp r ov ed C o m p on e nt Li st: Se ct i on 28, Eq u i pm en t Li st s f o r M ari n e A pp l i cati on, on pa ge s 12 8 t hroug h 1 31 of t he m an ua l i d en t i f i ed ab ov e. TES T R EPO R TS: R et l i f Test i ng Labor at or i es r epor t s.

R- 1576 9 dat ed D ecem ber 17, 2015. M a y n ot be i n st a l l e d i n l o cati o n s r e q u i r i n g an ex ce p t i on al d e g r ee of p r otect i o n, su ch as l o ca t i on e x p os e d t o w e athe r, se as, sp l ash i n g, p r e ssu r e - d i r e ct e d l i q u i d s, o r si m i l a r m oi st u r e co n i ti o n s. T e se o ca ti o n s i n c u e o ca ti o n s w i t i n a g a e y o r p a n tr y a re a, a u n ry, o r w a t e r c o se t w i c co n t a i n s a s o w e r o r a t; on e c; m a c i n e ry sp a ce s; ca rgo sp a ce s; a n othe r spa ce s w i t h si m i l a r en vi r on m en t a l co n d i t i o n s. T e s yst em m ust e i nst a e an con i gu r e i n acc or ance w i t Su par t 16 1. 00 2 an Su c apt er J of Ti t l e 46 of t he U.

C ode of Feder al R eg ul at i ons, and w i t h t he 199 3 or l at er ver s i on of N FP A 7 2. Th i s i s i n a d d i t i on t o a n y o t h e r r e q u i r e m e n t s spe ci f i c t o the v e sse l an d i t s r o u t e. O nl y t hose com po nen t s l i st ed on t he ap pr oved com po nen t l i st m ay b e u sed. TERMS: The approval o f the item described on the face of the Certifi cate has been based upon the submittal of satisfactory evidence that the item complies with the applicable p rovisions of the navigation and shipping laws and the applicable regul ations in Title 33 and/or Title 46 of the Code of Federal Regulations. The approval is subject to any conditions noted on th is Certificate and in the applicable laws and regu lations governing the use of the item on vessels subject to Coast Guard inspection or on other vessels and boats.

Consideration will be given to an extension of this approval provided application is made 3 months prior to the expiration date of this Certificate. The approval holder is responsible for making sure that the required inspections or tests of materials or devices covered by this approval are carried out during production as prescribed in the applicable regulations. The approval of the item covered by this certificate is valid only so long as the item is manufactured in conformance with the details of the approved drawings, specifications, or other data referred to.

Cerberus Addressable Fire Panel Manual Fc924-ut

No modification in the approved design, construction, or materials is to be adopted until the modification has been presented for consideration by the Commandant and confirmation received that the proposed alteration is acceptable. NOTICE: Where a manufacturer of saf ety-at-sea equipment is offering for sale to the maritime industry, directly or i ndirectly, equipment represented to be approved, which fails to conform with either the design details or material specifications, or both, as approved by the Coast Guar d, immediate action may be taken to invoke the various penalties and sanctions provided by law including prosecution under 46 U.S.C. 3318, which provides: 'A person that knowingly manufactures, sells, offers for sale, or possesses with intent to sell, any equipment subject to this part.

At the center of the system is an addressable 1-loop fire control panel of the FC360 series. The compact panels are intuitive to operate and you can connect up to 126 C-NET detectors and peripheral devices, including ASA neural fire detectors with the unique ASAtechnology™ from Siemens.

Cerberus addressable fire panel manual fc924-utManual

Your plus: the detectors offer outstanding detection reliability and immunity to false alarms in any environment. And because Cerberus FIT is an open maintenance system you can choose any maintenance provider once your system is installed and commissioned. What’s more, Cerberus FIT is an EN-compliant fire protection system. It is approved and certified by independent certified by the independent certification body, LPCB. Trust in the known and proven quality from Siemens ‒ and enhance safety with Cerberus FIT.

Coments are closed